Test Method and Standard of Antistatic Performance
The antistatic performance can be checked by testing surface resistance and decay time of film.
Test Method Standard:
ASTM (American Society for Testing Materials)
ASTM D257 Standard Test Method for DC Resistance of Conductance of Insulating Materials
ANSI (American National Standards Institute)/ESD(Electro-Static Discharge)
ANSI/ESD STM4.2 Test Method for Protection of Electrostatic Discharge Susceptible Items - ESD Protective Worksurfaces Charge Dissipation Characteristics
Test instrument:
Surface Resistance: Agilent 4339B High-Resistance Meter, DC and 16008B Resistivity Cell
Analysis of Results:
Surface Resistance(Ω) |
Half-life Time(S) |
Grade |
1010-1011 |
1-10 |
Excellent |
1011-1012 |
10-60 |
Good |
1012-1013 |
60-100 |
Qualified |
> 1013 |
> 100 |
Disqualified |
The purchase information of High-Resistance Meter:
Agilent sells products through agents in different areas. Many customers ask about the purchase information of the High-Resistance Meter. Therefore, we are posting the information of its agents on the website for customers’ reference.
General Agent in East China: Shanghai Jingce Electronics Co., Ltd.
Sales Manager:Yiming Wang
Mobil:+86-13611836035